Thermal Control System to Easily Cool the GAPS Balloon-borne Instrument on the Ground [IMA]

http://arxiv.org/abs/2212.12862


This study developed a novel thermal control system to cool detectors of the General AntiParticle Spectrometer (GAPS) before its flights. GAPS is a balloon-borne cosmic-ray observation experiment. In its payload, GAPS contains over 1000 silicon detectors that must be cooled below $-40^{\circ}\mbox{C}$. All detectors are thermally coupled to a unique heat-pipe system (HPS) that transfers heat from the detectors to a radiator. The radiator is designed to be cooled below $-50^{\circ}\mbox{C}$ during the flight by exposure to space. The pre-flight state of the detectors is checked on the ground at 1 atm and ambient room temperature, but the radiator cannot be similarly cooled. The authors have developed a ground cooling system (GCS) to chill the detectors for ground testing. The GCS consists of a cold plate, a chiller, and insulating foam. The cold plate is designed to be attached to the radiator and cooled by a coolant pumped by the chiller. The payload configuration, including the HPS, can be the same as that of the flight. The GCS design was validated by thermal tests using a scale model. The GCS design is simple and provides a practical guideline, including a simple estimation of appropriate thermal insulation thickness, which can be easily adapted to other applications.

Read this paper on arXiv…

H. Fuke, S. Okazaki, A. Kawachi, et. al.
Tue, 27 Dec 22
23/30

Comments: 8 pages, 14 figures, 3 tables