Radon variation measurements at the Yangyang underground laboratory [CL]

http://arxiv.org/abs/2209.00737


From October 2004 to May 2022, the concentration of radon in the air was measured at a depth of 700 m in the Yangyang underground laboratory. The average rates in the two experimental areas, called A6 and A5, were measured as 53.4\pm0.2 Bq/m^3 and 33.5\pm0.1 Bq/m^3, respectively. The lower rate in the A5 area was caused by the improved temperature control and ventilation. In particular, these radon rates are correlated to the local temperature of the area, with a correlation coefficient r = 0.22. Therefore, the radon rates displayed a seasonal variation, because the local temperature driven by the overground season influences air ventilation in the experimental areas. A cosine fit on the annual residual rates exhibited the maximum amplitude on August 31 \pm 6 d every year.

Read this paper on arXiv…

C. Ha, W. Kang, J. Kim, et. al.
Mon, 5 Sep 22
25/53

Comments: 6 pages, 6 figures