The Einstein Telescope (ET) is a third generation gravitational wave detector that includes a room-temperature high-frequency (ET-HF) and a cryogenic low-frequency laser interferometer (ET-LF). The cryogenic ET-LF is crucial for exploiting the full scientific potential of ET. We present a new baseline design for the cryogenic payload that is thermally and mechanically consistent and compatible with the design sensitivity curve of ET. The design includes two options for the heat extraction from the marionette, based on a monocrystalline high-conductivity marionette suspension fiber and a thin-wall titanium tube filled with static He-II, respectively. Following a detailed description of the design options and the suspension thermal noise (STN) modelling, we present the sensitivity curves of the two baseline designs, discuss the influence of various design parameters on the sensitivity of ET-LF and conclude with an outlook to future R&D activities.
X. Koroveshi, L. Busch, E. Majorana, et. al.
Wed, 3 May 23
2/67
Comments: 20 pages, Article to be published/submitted in Physical Review D – Journal