Strain Mapping by Digital laser Speckle Correlation, Validation and Comparison [IMA]

http://arxiv.org/abs/2001.03840


This Paper introduces a new Non-Contact, Optical method for displacement measurements, and strain mapping as well as comparing it to traditional Digital Image correlation (DIC) and laser interferometry measurement method. This Method incorporates diffracted laser speckle images from the surfaces through DIC to track displacement and locate strain values. In order to evaluate the feasibility of the method, various experiments were done and results were compared to laser interferometry based and traditional DIC. All the experiments were designed and done with affordable equipment, while they resulted in displacement as small as 30 micro-meter detection. Results presented by this paper are showing that DilSIC is an economic, accurate, rapid and applicable method for the mentioned purpose. Since it does not require any artifact speckle pattern, it can be used on the non-accessible area, limits and difficulties for creating speckle pattern is not applicable for this technique. In this research, various magnitude of strains have been examined within the range of [0-10%]. As this technique is a hybrid method of DIC and Laser speckle measurement it could eliminate some of the limits that everyone has. Those removed restrictions include but not limited to being able to measure strain within range of [0-10%] while using fringes on laser speckle does not let the measurement exceed 2%. Also using laser speckle pattern can end all the challenges to achieve the qualified speckle pattern as they can be adjusted to match the requirement easily.

Read this paper on arXiv…

M. Mosayebi
Tue, 14 Jan 20
61/72

Comments: N/A