Performance of 20:1 multiplexer for large area charge readouts in directional dark matter TPC detectors [CL]

http://arxiv.org/abs/1711.00943


More target mass is required in current TPC based directional dark matter detectors for improved detector sensitivity. This can be achieved by scaling up the detector volumes, but this results in the need for more analogue signal channels. A possible solution to reducing the overall cost of the charge readout electronics is to multiplex the signal readout channels. Here, we present work on an expanded LMH6574 multiplexer system with a capability of reducing the number of readouts in such TPC detectors by a factor of 20. Results indicate that the important charge distribution asymmetry along an ionization track is retained after multiplexed signals are demultiplexed.

Read this paper on arXiv…

A. Ezeribe, M. Robinson, N. Robinson, et. al.
Mon, 6 Nov 17
50/53

Comments: 12 pages, 9 figures